Delta AS Series Operation Manual page 72

Hide thumbs Also See for AS Series:
Table of Contents

Advertisement

Analog-to-Digital
Conversion
Rated Input Range
Rated Conversion
Range
Hardware Input
-20.24 mA ~ 20.24 mA
1
Limit*
2
Conversion Limit*
Error Rate
Hardware Resolution
Input Impedance
Absolute Input
3
Range*
*1: If the input signal exceeds the hardware input limit, the module only shows the maximum value. If the input
signal is below the lower limit, it only shows the minimum value.
*2: If the input signal exceeds the hardware input limit, it also exceeds the conversion limit and a conversion
limit error appears. For example in the voltage input mode (4 mA to 20 mA), when the input signal is 0 mA,
exceeding the hardware upper limit, it also exceeds the conversion upper limit. The module uses the upper
limit value (-384) as the input signal and a conversion limit error appears.
*3: If an input signal exceeds the absolute range, it might damage the channel.
Functional specifications for the digital-to-analog conversion
Digital-to-Analog
Conversion
Rated Output Range
Conversion Range
Hardware Output Range
Error Rate
(Room Temperature)
Error Range
(Full temperature range)
Linearity Error
(Room Temperature)
Linearity Error
(Full Temperature Range)
Hardware Resolution
Permissible load
impedance
2 - 3 8
C h a p t e r 2 S p e c i f i c a t i o n s a n d S y s t e m C o n f i g u r a t i o
Current Input
±20 mA
0 mA–20 mA
K-32000
~
K+2000
-0.24 mA ~ 20.24 mA
K-32384
~
K32384
Room Temperature: ±0.2% ; Full Temperature Range: ±0.5%
0 ~ 10 V
±10 V
K-32000
K0
~
~
K32000
K32000
-10.1 V
-0.1 V
~
~
+10.1 V
10.1 V
≧1k Ω
4 mA–20 mA
K0
~
K32000
3.81 mA ~ 20.19 mA
K-384
~
K32384
16 bits
250Ω
±32 mA
Voltage Output
0 ~ 5 V
±5 V
K-32000
K0
~
~
K32000
K32000
-5.05 V
-0.05 V
~
~
+5.05 V
+5.05 V
±0.2%
±0.5%
±0.05%
±0.05%
12 bits
≧500Ω
n
K0
~
K32000
K-384
~
K32384
1 ~ 5 V
K0
~
K32000
0.95
~
5.05 V