Kyocera TASKalfa 3050ci Service Manual page 568

Hide thumbs Also See for TASKalfa 3050ci:
Table of Contents

Advertisement

Connector
Pin
YC6
1
GND
Connected to
2
JOB_SET
feed PWB 1
3
JOB_MOT_REM
4
JOB_MOT_CLK
5
JOB_MOT_DIR
6
JOB_OPEN_SEN
S
7
JOB_SOL_REM
8
GND
9
MAIN_HEAT_RE
M
10
SUB_HEAT_REM
11
ZEROC
12
FSR_RELAY
13
PRESS_REM
14
EXIT_REAR_FAN
_L
15
EXIT_REAR_FAN
_H
16
GND
17
FSR_CL_REM
18
FSR_MOT_REM
19
FSR_MOT_CLK
20
FSR_MOT_RDY
21
FSR_MOT_DIR
22
FSR_MOT_BRK
23
GND
24
MPF_TABLE
25
MPF_WID1
26
MPF_WID2
27
MPF_WID3
28
MPF_LNG
29
GND
30
MPF_PPR_SET
31
MPF_LIFT_UP
32
MPF_LIFT_DOW
N
33
MPF_JAM
Signal
I/O
-
-
I
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC (pulse) JSEM clock signal
O
0/3.3 V DC
I
0/3.3 V DC
O
0/24 V DC
-
-
-
-
-
-
-
-
O
0/3.3 V DC
-
-
O
0/24 V DC
O
0/24 V DC
-
-
-
-
O
0/3.3 V DC
0/3.3 V DC (pulse) FUM clock signal
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
-
-
I
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC
-
-
I
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC
Voltage
Ground
Job separator set signal
JSEM: On/Off
JSEM drive switch signal
JSOCS: On/Off
JSFSSOL: On/Off
Ground
Not used
Not used
Not used
Fuser relay signal
Not used
ERFM: On/Off
ERFM: On/Off
Ground
Not used
FUM: On/Off
FUM ready signal
FUM drive switch signal
FUM break signal
Ground
MPTSW: On/Off
MPPWSW: On/Off
MPPWSW: On/Off
MPPWSW: On/Off
MPPLSW: On/Off
Ground
MPPS: On/Off
MPLS1: On/Off
MPLS2: On/Off
MPFS: On/Off
2-3-18
2LK/2LN/2LM/2LC-2
Description

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Taskalfa 3550ciTaskalfa 4550ciTaskalfa 5550ci

Table of Contents