Code
Contents
6710
Fuser IH PWB CPU reset
error
Watch doc timer has been
overflowed.
6720
Fuser IH belt rotation error
A belt rotating pulse is not
received for 1 second.
6730
Abnormally high fuser IH
PWB temperature 1
The input detect temperature
is greater than 105°C/221 °F.
6740
Abnormally high fuser IH
PWB temperature 2
The input detect temperature
is greater than 105°C/221 °F.
6750
Fuser IH output over-cur-
rent error
The output current is greater
than 75A for 10 ms in succes-
sion.
Causes
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Fuser IH PWB (YC4) and engine PWB
(YC26)
Defective fuser IH
Replace the fuser IH PWB and check for
PWB.
correct operation.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-54).
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Fuser unit and engine PWB (YC26)
Defective fuser belt
Replace the fuser belt sensor.
sensor.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-54).
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Fuser IH PWB (YC4) and engine PWB
(YC26)
Defective fuser IH
Replace the fuser IH PWB and check for
PWB.
correct operation.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-54).
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Fuser IH PWB (YC4) and engine PWB
(YC26)
Defective fuser IH
Replace the fuser IH PWB and check for
PWB.
correct operation.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-54).
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Fuser IH PWB (YC4) and engine PWB
(YC26)
Defective fuser IH
Replace the fuser IH PWB and check for
PWB.
correct operation.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-54).
1-4-60
2LK/2LN/2LM/2LC
Check procedures/
corrective measures

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Taskalfa 3550ciTaskalfa 4550ciTaskalfa 5550ci

Table of Contents