17. Remove two stop rings.
18. Remove two bushes.
19. Pull the retard MPF shaft out and then
remove the torque limiter and the MP
separation pulley.
20. Clean or replace the MP forwarding pul-
ley, MP paper feed pulley and MP sepa-
ration pulley.
21. Refit the MP forwarding pulley, MP
paper feed pulley and MP separation
pulley to the MP tray paper feed unit.
22. When the MP forwarding pulley, MP
paper feed pulley or MP separation pul-
ley is replaced, perform maintenance
mode U903 (clearing the jam counter)
(see page 1-3-188).
Torque limiter
MP separation
pulley
Bush
Stop ring
Figure 1-5-30
1-5-18
2LK/2LN/2LM/2LC
Retard MPF shaft
Bush
Stop ring
Retard holder