Kyocera TASKalfa 3050ci Service Manual page 370

Hide thumbs Also See for TASKalfa 3050ci:
Table of Contents

Advertisement

Code
Contents
7912
Developer unit C EEPROM
error
No response is issued from
the device in reading/writing
for 5 ms or more and this
problem is repeated five times
successively.
Mismatch of reading data from
two locations occurs 8 times
successively.
Mismatch between writing
data and reading data occurs
8 times successively.
7913
Developer unit M EEPROM
error
No response is issued from
the device in reading/writing
for 5 ms or more and this
problem is repeated five times
successively.
Mismatch of reading data from
two locations occurs 8 times
successively.
Mismatch between writing
data and reading data occurs
8 times successively.
7914
Developer unit Y EEPROM
error
No response is issued from
the device in reading/writing
for 5 ms or more and this
problem is repeated five times
successively.
Mismatch of reading data from
two locations occurs 8 times
successively.
Mismatch between writing
data and reading data occurs
8 times successively.
Causes
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Developer unit C and front PWB (YC13)
Front PWB (YC2) and engine PWB (YC10)
Defective devel-
Replace the developer unit C (see page 1-5-
oper unit C.
36).
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Developer unit M and front PWB (YC11)
Front PWB (YC2) and engine PWB (YC10)
Defective devel-
Replace the developer unit M (see page 1-5-
oper unit M.
36).
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Developer unit Y and front PWB (YC15)
Front PWB (YC2) and engine PWB (YC10)
Defective devel-
Replace the developer unit Y (see page 1-5-
oper unit Y.
36).
1-4-72
2LK/2LN/2LM/2LC
Check procedures/
corrective measures

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Taskalfa 3550ciTaskalfa 4550ciTaskalfa 5550ci

Table of Contents