Item No.
U161
Setting the fuser control temperature
Description
Changes the fuser control temperature.
Purpose
Normally no change is necessary. However, can be used to prevent curling or creasing of paper,
or solve a fuser problem on thick paper.
Method
1. Press the start key.
2. Select the item to be set.
Warm Up
Print
Setting: [Warm Up]
1. Select the item to be set.
2. Change the setting value using the +/- keys.
Display
Ready
(Center)
Ready
(Edge)
Ready
(Press)
Drive
(Center)
Wait
(Center)
Low Power
(Press)
Full Speed
Shift(Center)
Pressure
(Press)
3. Press the start key. The value is set.
Display
Control temperature except at printing
Control temperature during printing
Description
Control temperature at dis-
playing Ready (Center)
Control temperature at dis-
playing Ready (Edge)
Control temperature at dis-
playing Ready (Press)
Stable temperature during
driving (Center)
Stable temperature during
halt (Center)
Control temperature at low
power consumption
(Press)
Full speed shift tempera-
ture (Center)
Pressurizing beginning
temperature (Press)
Description
Description
Setting
range
130 to 200
(°C)
100 to 200
(°C)
0 to 200
(°C)
130 to 200
(°C)
130 to 200
(°C)
0 to 200
(°C)
0 to 200
(°C)
0 to 200
(°C)
1-3-103
2LK/2LN/2LM/2LC-2
Initial setting
30ppm 35ppm 45ppm 55ppm
155
160
165
110
110
140
40
40
80
165
170
170
155
165
165
150
150
150
50
50
50
120
120
155
170
145
80
175
175
150
50
160