Table Of Contents - Kyocera TASKalfa 3050ci Service Manual

Hide thumbs Also See for TASKalfa 3050ci:
Table of Contents

Advertisement

Code
Contents
6020
Abnormally high fuser
thermistor 1 temperature
wire
6120
Abnormally high fuser
thermistor 4 temperature
wire
6220
Abnormally high fuser
thermistor 2 temperature
wire
wire
Com-
bined
6610
Fuser release motor error
When the fuser release motor
is driven, the fuser release
sensor does not turn on/off for
5 s.
Causes
Deformed connec-
If the I/F connector pins of the fuser unit and
tor pin.
the main unit are deformed owing to foreign
matters, such as paper dusts, replace the
connectors or the units including the con-
nectors.
Defective triac.
Remove the power cord and check that the
resistance between terminals T1 and T2 of
the triac CR001 is of several Mega-Ohms
and not shorted (see figure 1-4-4). If failed,
replace the power source PWB (see page 1-
5-56).
CR001
Power source PWB
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Fuser unit and engine PWB (YC26)
Defective drive
Check if the gears rotate smoothly. If not,
transmission sys-
grease the bushes and gears. Check for
tem of motor.
broken gears and replace if any.
Defective fuser
Replace the fuser release motor.
release motor.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-54).
1-4-59
2LK/2LN/2LM/2LC-2
Check procedures/
corrective measures
T1
T2
Figure 1-4-4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Taskalfa 3550ciTaskalfa 4550ciTaskalfa 5550ci

Table of Contents