(6) Detaching and refitting the operation PWB
Procedure
1. Pull the paper conveying unit out.
2. Remove the screw from the right upper
cover.
3. Open the front cover.
4. Remove the screw and then remove the
fan cover.
5. Unhook three hooks and then remove
the front upper right cover.
Right upper cover
Front upper
right cover
Screw
1-5-61
2LK/2LN/2LM/2LC-2
Screw
Figure 1-5-96
Fan cover
Figure 1-5-97
Hooks