Chapter 5 Trial Operation and Tuning

5.4 Trial Run without Load (Speed Mode)

Before the trial run without load, firmly secure the motor base so as to avoid the danger
cause by the reaction of motor operation.
STEP 1:
Set the control mode of the servo drive to speed mode. Set P1-01 to 2. Then, re-power on
the servo drive.
STEP 2:
In speed control mode, the digital input settings of trial run are as follows:
Parameter
Digital Input
Setting Value
DI1
P2-10 = 101
DI2
P2-11 = 109
DI3
P2-12 = 114
DI4
P2-13 = 115
DI5
P2-14 = 102
DI6
P2-15 = 0
DI7
P2-16 = 0
DI8
P2-17 = 0
DI9
P2-36 = 0
The above table disables the function of negative limit (DI6), positive limit (DI7) and
emergency stop (DI8). Thus, the value of parameter P2-15 ~ P2-17 and P2-36 is set to 0
(Disabled). The digital input of Delta's servo drive can be programmed by users. When
programming digital input, please refer to the description of DI code.
The default setting includes the function of negative limit, positive limit and emergency
stop, therefore, after the setting is completed, if there is any alarm occurs, please re-power
on the servo drive or switch ON DI5 to clear the alarm. Please refer to Chapter 5.2.
5-8
Symbol
Function Description
SON
TRQLM
SPD0
Speed command selection
SPD1
Speed command selection
ARST
Disabled
Invalid DI function
Disabled
Invalid DI function
Disabled
Invalid DI function
Disabled
Invalid DI function
Servo On
Torque limit
Alarm reset
ASDA-B2
CN1 PIN No.
DI1- = 9
DI2- = 10
DI3- = 34
DI4- = 8
DI5- = 33
-
-
-
-
Revision May, 2018