8
If there is no problem with the test page, press <Store and Finish>.
If the density of the test page after correction is uneven, perform the procedure indicated in
Correction(P. 1207) .
Visual Correction
Visually measure a test page you have output to perform correction using the density adjustment values you
determine. Use this procedure when you do not have a densitometer or when correction is not effective.
1
Press
<Adjustment/Maintenance>
Shading>
<Visual Correction>.
2
Press <Output Test Page>
A test page is printed.
3
Visually check the test page to determine the density adjustment values.
The range of marks printed for each color may be -6 to +6 or -5 to +5, depending on the paper size used
for the test page.
4
Press <Fine Adjust> for each color.
5
Enter the density values.
Enter the density values according to the results that you visually checked in step 3 from -6 to +6 (or -5 to +5)
for each color.
Enter a plus value to increase the density, or a minus value to decrease the density.
6
Press <OK>.
7
Press <Output Test Page>
A test page after correction is output.
8
If there is no problem with the test page, press <Store and Finish>.
Scanner Correction
You can perform density correction by scanning a test page that you have output. The machine automatically
determines density correction values and corrects irregularities.
Maintenance
<Adjust Image Quality>
<Start Printing>.
<Start Printing>.