2-24-5.Load Switching Frequency; 2-24-6.Muting Statistics Information - Omron F3SG-2RE0430P30 User Manual

Safety light curtain
Table of Contents

Advertisement

The user can make changes to the settings by the Configuration Tool.
Function
Power-on time threshold
2-24-5. Load Switching Frequency
The user can view the number of operations of the load connected to F3SG-RA. The number of load
operations can be used to understand the switching frequency of relays and contactors connected to
F3SG-RA.
It is possible to give an output signal to the auxiliary output or indicate with Lamp (F39-LP and F39-
BTLP, sold separately) when the number of operations exceeds the switching frequency threshold.
The excess load switching frequency information must be assigned to the output operation mode of
the auxiliary output or Lamp.
2-11. Auxiliary Output
2-21. Lamp
The user can make changes to the settings by the Configuration Tool.
Function
Load switching frequency threhshold
2-24-6. Muting Statistics Information
This function logs and visualizes conditions of F3SG-RA muting operations to help the user adjust
settings of muting input time difference. Also, its statistic calculation allows for optimal settings with
reduced test runs.
Refer to Safety Light Curtain Configuration Tool for Model F3SG (SD Manager 2) User's Manual for more
information on setting this function by the Configuration Tool.
Factory Default Setting
30,000 h
Factory Default Setting
100,000 times in 1-time increment 100,000 to 4,000,000 times in 1-time increments/
System Operation and Functions
Available Parameters
30,000 to 1,000,000 h in 1-h increments/Disable
Available Parameters
Disable
E
F3SG-R
105
User's Manual

Advertisement

Table of Contents
loading

Table of Contents