Warning Zone; 2-17-1.Overview - Omron F3SG series User Manual

Safety light curtain
Hide thumbs Also See for F3SG series:
Table of Contents

Advertisement

2-17. Warning Zone

F3SG-RA Series
F3SG-RE Series
2-17-1. Overview
Part of the detection zone can be set as a warning zone.
Example:
• When a person enters, indicator or buzzer should notify warning without stopping a machine.
The Warning Zone is not available for the F3SG-RE.
When a warning zone is configured, you must attach labels that indicate a border
between normal detection zone and warning zone. Otherwise the machine may not stop
before a person reaches to the hazardous part, resulting in serious injury.
A warning zone must not be used for safety applications. Always install your system so
that a detection zone should be passed before reaching a hazardous part of the machine.
If access to the hazardous part by reaching over the detection zone of a vertically
mounted F3SG-R cannot be excluded, the height of the detection zone and the safety dis-
tance shall be determined in consideration of such a risk.
A warning zone must be configured based on a safety distance.
Safety distance (S)
Detection
Hazard
Zone
Refer to 4-1-2. Safety Distance for more information on safety distance calculations for
orthogonal and parallel approaches.
X

Warning Zone

System Operation and Functions
Detection Zone
Warning Zone
Safety
Detection Zone
distance (S)
Hazard
Detection Zone
Warning Zone
F3SG-R
User's Manual
E
87

Advertisement

Table of Contents
loading

Table of Contents