YASKAWA A1000 Series Quick Start Manual page 178

High performance vector control drive
Hide thumbs Also See for A1000 Series:
Table of Contents

Advertisement

B Parameter List
U4: Maintenance Monitors
No.
Name
Cumulative Operation
U4-01
Time
Number of Run
U4-02
Commands
Cooling Fan Operation
U4-03
Time
Cooling Fan
U4-04
Maintenance
U4-05
Capacitor Maintenance
Soft Charge Bypass
U4-06
Relay Maintenance
U4-07
IGBT Maintenance
U4-08
Heatsink Temperature
U4-09
LED Check
U4-10
kWh, Lower 4 Digits
U4-11
kWh, Upper 5 Digits
U4-13
Peak Hold Current
Peak Hold Output
U4-14
Frequency
Motor Overload Estimate
U4-16
(oL1)
Frequency Reference
U4-18
Source Selection
Frequency Reference
U4-19
from MEMOBUS/
Modbus Comm.
Option Frequency
U4-20
Reference
178
Displays the cumulative operation time of the drive. The value for the
cumulative operation time counter can be reset in parameter o4-01. Use
parameter o4-02 to determine if the operation time should start as soon as the
power is switched on or only while the Run command is present. The
maximum number displayed is 99999, after which the value is reset to 0.
Displays the number of times the Run command is entered. Reset the number
of Run commands using parameter o4-13. This value will reset to 0 and start
counting again after reaching 65535.
Displays the cumulative operation time of the cooling fan. The default value
for the fan operation time is reset in parameter o4-03. This value will reset to
0 and start counting again after reaching 99999.
Displays main cooling fan usage time in as a percentage of its expected
performance life. Parameter o4-03 can be used to reset this monitor.
Displays main circuit capacitor usage time in as a percentage of their expected
performance life. Parameter o4-05 can be used to reset this monitor.
Displays the soft charge bypass relay maintenance time as a percentage of its
estimated performance life. Parameter o4-07 can be used to reset this monitor.
Displays IGBT usage time as a percentage of the expected performance life.
Parameter o4-09 can be used to reset this monitor.
Displays the heatsink temperature.
Lights all segments of the LED to verify that the display is working properly.
Monitors the drive output power. The value is shown as a 9 digit number
displayed across two monitor parameters, U4-10 and U4-11.
Example:
12345678.9 kWh is displayed as:
U4-10: 678.9 kWh
U4-11: 12345 MWh
Displays the highest current value that occurred during run.
Displays the output frequency when the current value shown in U4-13
occurred.
Shows the value of the motor overload detection accumulator. 100% is equal
to the oL1 detection level.
Displays the source for the frequency reference as XY-nn.
X: indicates which reference is used:
1 = Reference 1 (b1-01)
2 = Reference 2 (b1-15)
Y-nn: indicates the reference source
0-01 = Digital operator
1-01 = Analog (terminal A1)
1-02 = Analog (terminal A2)
1-03 = Analog (terminal A3)
2-02 to 17 = Multi-step speed (d1-02 to 17)
3-01 = MEMOBUS/Modbus communications
4-01 = Communication option card
5-01 = Pulse input
7-01 = DWEZ
Displays the frequency reference provided by MEMOBUS/Modbus
(decimal).
Displays the frequency reference input by an option card (decimal).
YASKAWA ELECTRIC TOEP C710616 21C YASKAWA AC Drive - A1000 Quick Start Guide
Description
Analog Output
Unit
Level
No signal output
1 h
available
No signal output
1 Time
available
No signal output
1 h
available
No signal output
1%
available
No signal output
1%
available
No signal output
1%
available
No signal output
1%
available
10 V: 100°C
1°C
No signal output
available
No signal output
1 kWh
available
No signal output
1 MWh
available
No signal output
0.01 A
available
<50>
No signal output
0.01 Hz
available
10 V: 100%
0.1%
No signal output
available
No signal output
0.01%
available
No signal output
available