No.
Name
Speed Agreement Detection
L4-07
Selection
<10> Default setting is determined by the control mode (A1-02).
L5: Fault Restart
No.
Name
Number of Auto Restart
L5-01
Attempts
Auto Restart Fault Output
L5-02
Operation Selection
L5-04
Fault Reset Interval Time
Fault Reset Operation
L5-05
Selection
L6: Torque Detection
No.
Name
L6-01
Torque Detection Selection 1
L6-02
Torque Detection Level 1
L6-03
Torque Detection Time 1
L6-04
Torque Detection Selection 2
L6-05
Torque Detection Level 2
L6-06
Torque Detection Time 2
YASKAWA ELECTRIC TOEP C710616 21C YASKAWA AC Drive - A1000 Quick Start Guide
0: No detection during baseblock.
1: Detection always enabled.
Sets the number of times the drive may attempt to restart after the following
faults occur: GF, LF, oC, ov, PF, rH, rr, oL1, oL2, oL3, oL4, STo, Uv1.
0: Fault output not active.
1: Fault output active during restart attempt.
Sets the amount of time to wait between performing fault restarts.
0: Continuously attempt to restart while incrementing restart counter only at a
successful restarts (same as F7 and G7).
1: Attempt to restart with the interval time set in L5-04 and increment the restart
counter with each attempt (same V7).
0: Disabled
1: oL3 detection only active during speed agree, operation continues after
detection
2: oL3 detection always active during run, operation continues after detection
3: oL3 detection only active during speed agree, output shuts down on an oL3
fault
4: oL3 detection always active during run, output shuts down on an oL3 fault
5: UL3 detection only active during speed agree, operation continues after
detection
6: UL3 detection always active during run, operation continues after detection
7: UL3 detection only active during speed agree, output shuts down on an oL3
fault
8: UL3 detection always active during run, output shuts down on an oL3 fault
Sets the overtorque and undertorque detection level.
Sets the time an overtorque or undertorque condition must exist to trigger torque
detection 1.
0: Disabled
1: oL4 detection only active during speed agree, operation continues after
detection
2: oL4 detection always active during run, operation continues after detection
3: oL4 detection only active during speed agree, output shuts down on an oL4
fault
4: oL4 detection always active during run, output shuts down on an oL4 fault
5: UL4 detection only active during speed agree, operation continues after
detection
6: UL4 detection always active during run, operation continues after detection
7: UL4 detection only active during speed agree, output shuts down on an oL4
fault
8: UL4 detection always active during run, output shuts down on an oL4 fault
Sets the overtorque and undertorque detection level.
Sets the time an overtorque or undertorque condition must exist to trigger torque
detection 2.
Description
Description
Description
B Parameter List
Setting
Default: 0
Min: 0
Max: 1
Setting
Default: 0
Min: 0
Max: 10
Default: 0
Min: 0
Max: 1
Default: 10.0 s
Min: 0.5 s
Max: 600.0 s
Default: 0
Min: 0
Max: 1
Setting
Default: 0
Min: 0
Max: 8
Default: 150%
Min: 0%
Max: 300%
Default: 0.1 s
Min: 0.0 s
Max: 10.0 s
Default: 0
Min: 0
Max: 8
Default: 150%
Min: 0%
Max: 300%
Default: 0.1 s
Min: 0.0 s
Max: 10.0 s
B