YASKAWA A1000 Series Quick Start Manual page 114

High performance vector control drive
Hide thumbs Also See for A1000 Series:
Table of Contents

Advertisement

5 Troubleshooting
Digital Operator Display
End6
Cause
The leakage inductance value that was
calculated is outside the allowable range.
Digital Operator Display
End7
Cause
The entered no-load current value was
outside the allowable range.
Auto-Tuning results were less than 5%
of the motor rated current.
Digital Operator Display
Er-01
Cause
Motor data or data entered during
Auto-Tuning was incorrect.
Motor output power and motor-rated
current settings (T1-02 and T1-04) do
not match.
Motor rated current and detected no-load
current are not consistent with another.
Base frequency and motor rated speed
(T1-05 and T1-07) do not match.
Digital Operator Display
Er-02
Cause
An alarm was triggered during Auto-
Tuning.
Digital Operator Display
Er-03
Cause
Auto-Tuning canceled by pressing STOP
button.
Digital Operator Display
Er-04
Cause
Motor data entered during Auto-Tuning
was incorrect.
Results from Auto-Tuning are outside
the parameter setting range or the tuning
process took too long.
Motor cable or cable connection faulty.
Digital Operator Display
Er-05
Cause
Motor data entered during Auto-Tuning
was incorrect.
Results from Auto-Tuning are outside
the parameter setting range or the tuning
process took too long.
The load during Rotational Auto-tuning
was too high.
114
Leakage Inductance Alarm
Double check the data that was entered for the Auto-Tuning process.
No-Load Current Alarm
Check and correct faulty motor wiring.
Double check the data that was entered for the Auto-Tuning process.
Motor Data Error
• Check that the motor data entered to T1 parameters matches motor nameplate input before Auto-
Tuning.
• Start Auto-Tuning over again and enter the correct information.
• Check the drive and motor capacities.
• Correct the settings of parameters T1-02 and T1-04.
• Check the motor rated current and no-load current.
• Correct the settings of parameters T1-04 and E2-03.
• Set T1-05 and T1-07 to the correct value.
• Check if the correct pole number was entered to T1-06.
Minor Fault
Exit the Auto-Tuning menu, check the alarm code, remove the alarm cause, and repeat Auto-Tuning.
STOP Button Input
Auto-Tuning did not complete properly and will have to be performed again.
Line-to-Line Resistance Error
• Make sure the data entered to the T1 parameters match the information written on the motor
nameplate.
• Restart Auto-Tuning and enter the correct information.
Check and correct faulty motor wiring.
No-Load Current Error
• Make sure the data entered to the T1 parameters match the information written on the motor
nameplate.
• Restart Auto-Tuning and enter the correct information.
• Check and correct faulty motor wiring.
• Perform Rotational Auto-Tuning.
• Disconnect the motor from machine and restart Auto-Tuning. If motor and load cannot be uncoupled
make sure the load is lower than 30%.
• If a mechanical brake is installed, make sure it is fully lifted during tuning.
YASKAWA ELECTRIC TOEP C710616 21C YASKAWA AC Drive - A1000 Quick Start Guide
Error Name
Possible Solutions
Error Name
Possible Solutions
Error Name
Possible Solutions
Error Name
Possible Solutions
Error Name
Possible Solutions
Error Name
Possible Solutions
Error Name
Possible Solutions

Advertisement

Table of Contents
loading

Table of Contents