7. For FCR-29 or FAR-27 series antenna unit, perform the self test to confirm
that the SPU program version and DIP switch setting are as shown below.
For FCR-29 series
Open the [System Monitor] menu (see section 1.11), then click the [Self-test] but-
ton[Radar Sensor (FCR-29)][Sensor Status].
[SPU Software Version]: 0359204-03.50, or after
[SPU DIP switch (SW16-SW1)]: 0100
For FAR-27 series
Perform the self test, referring the operator's manual of FAR-27 series radar.
[SPU PROGRAM NO.]: 0359204-03.50, or after
[DIP SW]: 1000 or 1001
1.4.6

Radar connection box configuration (ECDIS only)

You can display echoes from non-Furuno radars by connecting them to the ECDIS
through the Radar Connection Box RCB-002. A maximum of four RCB-002s can be
connected to this system.
Set the location information of the external radar antenna on the [Own Ship Setting]
menu (see page 1-14) before doing the procedure shown below.
Note: When multiple RCB-002s are connected to the same network, change the IP
address of the RCB-002s, referring to "RCB-002 IP ADDRESS
SETTING" on page AP-4.
1. Click [Radar Connection Box] on the menu bar.
2. Click the check box for [RCB00 (Main)] (: 1 to 4). This box must be checked to
use the radar connection box.
3. When you connect two external radars to the radar connection box, click the
check box for [RCB00 (Sub)] (: 1 to 4).
4. Click the [Details] button and set the following items.
For "Main" radar
1. INITIAL SETTING AND ADJUSTMENT
For "Sub" radar
1-31