Furuno FMD-3200-BB Instruction Manual page 35

Setting and adjustments
Hide thumbs Also See for FMD-3200-BB:
Table of Contents

Advertisement

10. Check the checkbox for [Channel No.] to set the items referring to step 12 of
section 1.4.2.
11. Click [Analog Input] on the menu bar.
[Channel 01] to [Channel 15] are shown on the display. Each Sensor Adapter MC-
3010A has three input ports. When one Sensor Adapter MC-3010A is connected
to the MC-3000S, [Channel 01] to [Channel 03] can be used. When five Sensor
Adapters MC-3010A are connected, [Channel 01] to [Channel 15] can be used.
The connector no. on the MC-3010A board and corresponding serial port no. are
shown in the following table.
12. Check the checkbox for [Channel No.] to set the items referring to the table shown
below.
Item
[Sensor Name]
Enter an appropriate name that indicates sensor's function.
[Data Type]
Sets the input data type. Setting range: -10-10V, 0-10V, 4-20mA.
Note: For [4-20mA], fix the jumper to the connector (J3 to J5). See the
installation manual of ECDIS or Chart Radar.
1. INITIAL SETTING AND ADJUSTMENT
No.1 MC-3010A
Connector No.
Channel No.
J3
Channel 01
J4
Channel 02
J5
Channel 03
No.2 MC-3010A
Connector No.
Channel No.
J3
Channel 04
J4
Channel 05
J5
Channel 06
Remarks