1. INITIAL SETTING AND ADJUSTMENT
[Input Unit]
[Is Active]
[Priority]
[Category]
[Emergency Icon]
[Emergency Buzzer]
[Escalation Mode]
[Escalation Time]
[Escalation Transfer]
[Transfer Time]
[Integrated Alert]
[Send VDR]
[Clear Non-Ack Alert
when Rectified]
[Detailed Information]
3. Click the [OK] button to close the [New Alert] window.
4. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.
1-66
Item
Select the input source for the alert.
• For other than sensors: [Internal], [Digital]
• For sensors: [CCRS], [Digital], [MODBUS]
Activate/Deactivate the alert. [YES]: activated, [NO]: deacti-
vated.
The priority of the alert group ([Emergency]/[Alarm]/[Warn-
ing]/[Caution]).
The category of the alert group (A to C).
Select the icon for the emergency alert. Available only for
alerts with [Priority] set to [Emergency].
Select the buzzer sound for the emergency alert. Available
only for alerts with [Priority] set to [Emergency].
Select the priority that escalates the status of an alert,
[Alarm] or [Warning]. Available only for alerts with [Priority]
set to [Warning].
• [Alarm]: When the alert is left unacknowledged, the priority
is changed to [Alarm].
• [Warning]: When the alert is left unacknowledged, the pri-
ority remains as [Warning]. Then, the alert buzzer sounds
again.
Set the time to wait before activating the escalation function
against an alert. Available only for alerts with [Priority] set to
[Warning].
Enable or disable transfer of an Alarm priority alert in the
transfer escalation mode. Available only for alerts with [Es-
calation Mode] set to [Alarm].
Set the time to wait before transferring an Alarm priority alert
in the transfer escalation mode. Available only for alerts with
[Escalation Mode] set to [Alarm].
Keep the default setting.
Select [YES] to transfer the ALR sentence to the VDR.
Select [YES] to delete the non-acknowledged alerts auto-
matically when they are rectified.
Enter the detail information (max. 1023 characters) of the
alert.