1. INITIAL SETTING AND ADJUSTMENT
• Present Leg
• Speed And Transverse
[Title]: Enter the title of the component.
[Location]: Select the reference point for the speed from the pull-down list.
[Speed Label]: Enter the title shown at the upper of the longitudinal speed value.
[Transverse Label]: Enter the title shown at the upper of the transverse speed value.
[SOG Longitudinal Speed]: Select the data source of the longitudinal SOG.
[STW Longitudinal Speed]: Select the data source of the longitudinal STW.
[CCRP Transverse Speed]: Select the data source of the longitudinal speed at the
CCRP position.
[Bow Transverse Speed]: Select the data source of the longitudinal speed at the
bow position.
[Stern Transverse Speed]: Select the data source of the longitudinal speed at the
stern position.
[Speed Type Source]: Select the data source same as [Longitudinal Speed Source]
to show the abbreviated name of the data source unit.
[Sensor Name Source]: Select the appropriate sensor name source.
[Unit]: Set the unit of the ship's speed.
[Decimal Place]: Check the checkbox to show the value after decimal point
[Mathematical Sign]: Check the checkbox to show the minus sign (-) when the value
is a negative figure.
1-96