Drs Radar Sensor Connections - Furuno TZtouchXL TZT22X Installation Manual

Multi function display
Hide thumbs Also See for TZtouchXL TZT22X:
Table of Contents

Advertisement

2.3.1
How to set up NMEA 0183 data output
Note: To set up data input from NMEA 0183 equipment, see "NMEA 0183 equipment
data input" on page 2-4.
1. Tap the [FURUNO] icon (
mode settings.
2. Tap [Settings], then drag the menu to show [Initial Setup]. Tap [Initial Setup].
3. Tap [Data Sensors], then tap [NMEA0183 Output].
4. Tap [Baud Rate] to set the output baud rate. Available options are [4,800], [9,600]
and [38,400].
5. Tap the appropriate setting then tap the
6. Tap [NMEA-0183 Version] to set the version. Available options are [1.5], [2.0] and
[3.0].
7. Tap the appropriate setting then tap the
8. Select the sentences to output. Tap a sentence, then tap its flipswitch to set the
sentence to [ON].
9. Tap the [Close] icon at the top right of the screen to close the menus.
2.4

DRS Radar Sensor Connections

The figures below show connection examples with radar sensors which are compati-
ble with the TZT22X/24X.
For details regarding connection and cables required for connection with the radar
sensor, see the radar sensor's installation manual.
Note: DRS2D-NXT and DRS4D-NXT cannot be used in Japan.
DRS4D X-Class is for Japanese market only.
Connection examples for radome sensors
DRS4D X-Class/DRS4DL+
DRS2D-NXT/DRS4D-NXT
To ship mains
(12 to 24 VDC)
HUB-101
TZT22X/TZT24X
) to show the home screen and display
icon.
icon.
Connection examples for open-array sensors
DRS6A X-Class/DRS12A X-Class/
DRS25A X-ClassDRS6A-NXT/
DRS12A-NXT/ DRS25A-NXT
To ship mains
(12* to 24 VDC)
HUB-101
*: 12 VDC is only used
with DRS6A-NXT. All
other open array DRS
sensors require 24
VDC.
TZT22X/TZT24X
2. WIRING