1. INITIAL SETTING AND ADJUSTMENT
Manufacturer
Yokogawa
Electric
Corporation
TOKYO KEIKI
EMRI
10. Open the [Digital Output Setting] window of the ECDIS connected to the autopilot.
11. Check the channel no. connected to the BNWAS (Bridge Navigation Watch Alarm
System).
12. Set [Data Type] and [Data Category] as shown below.
• [Data Type]: According to the BNWAS, select [NO] (Normal Open) or [NC] (Nor-
mal Close).
• [Data Category]: Select [BACKUP NAVIGATOR].
13. Click [CCRS] on the menu bar.
14. For the sensor data listed below, register the data source and filter, with Priority
of Data Source on the CCRS menu.
The filter must be set to No.1 priority. For example, when No.1 ECDIS connected
to the autopilot, set the filter "ECD001/FILTER (IN0001)" to No.1 priority.
• Position
• STW (absolute)
• STW (position)
• COG/SOG
• Rate of Turn
15. Click [TCS] on the menu bar.
1-44
Model
Sentence
PT-900
• HTC
• XTE
• VBW
• VTG
PR-6000
• HTC
or
• XTE
PR-9000
• VBW
• VTG
• HSC
• FRN
FAP-2000
• ESS
or
FAP-3000
Example: For the position data
Display example
Set the filter to
No.1 priority.