Furuno FMD-3200-BB Instruction Manual page 29

Setting and adjustments
Hide thumbs Also See for FMD-3200-BB:
Table of Contents

Advertisement

10. Click [Digital Output] of [No.1 ECDIS] or [No.1 Chart Radar] on the menu bar.
For the pin no. of J11 on the I/O board of the processor unit and the corresponding
input/output channel no., see the table on step 7.
11. Check the checkbox for [Channel No.].
12. Set the items referring to the table shown below.
Item
[Data Cate-
Sets the data category. Settings: [ALERT], [ACK], [BUZZER STOP], [OP-
gory]
ERATOR FITNESS], [OTHER], [TRANSFER], [BACKUP NAVIGATOR].
[+] button
This appears when the [Data Category] is set to [ALERT]. Click to show
the configuration of the alert output.
• [Equipment ID]: The Equipment ID is shown.
• [Alert ID]: The alert notification sentence* (ALF or ALR) and alert num-
ber are shown. When the alert notification sentence is ALF, the in-
stance ID is shown.
*: According to setting of [Output Data Type for INS] in the [AMS] menu
(see section 1.7).
• [
alert. The following example uses the alert notification sentence ALF.
Check the radio button of the desired alert and click the [OK] button.
• [Alert Name]: The alert name is shown.
[Equipment
Select the Equipment ID from the pull-down list.
ID]
The pull-down list options change according to the setting at [Sensor Set-
ting].
Example: ALF is the alert notification sentence.
] button: Opens the [Alert No. Setting] window to select the output
1. INITIAL SETTING AND ADJUSTMENT
Remarks