Kodak MULTILOADER 700 Service Manual page 45

Hide thumbs Also See for MULTILOADER 700:
Table of Contents

Advertisement

REPLACEMENTS
4
.
Take off VACUUM TUBING. PUMP runs.
5
.
Switch off VACUUM PUMPS off (press KEY # 2).
6
.
Connect VACUUM TUBING.
7
.
Connect the VACUUM GAUGE
8
.
Switch on the VACUUM PUMPS (Option 7.8.2).
9
.
Switch on MAGAZINE SUCKING (Option 7.8.4).
10.
Cover MAGAZINE SUCKERS with a FILM.
11.
Loosen the LOCK NUT and adjust with the BRASS NUT the vacuum
to -400 mBar - 30 mBar. See the drawing on the next page.
12.
Tighten the LOCK NUT.
KODAK AG, Stuttgart
Connect the VACUUM GAUGE here
figure 2-17
2-21
3053-3
12/1998

Advertisement

Table of Contents
loading

This manual is also suitable for:

Multiloader 700 plus

Table of Contents