REPLACEMENTS
8
.
Switch on the VACUUM PUMPS (Option 7.8.2).
9
.
Switch on CASSETTE SUCKING (Option 7.8.3).
10.
Cover CASSETTE SUCKERS with a FILM.
11.
Loosen the LOCK NUT and adjust with the BRASS NUT the vacuum
to -400 mBar - 30 mBar
VACUUM PUMP CASSETTE
VACUUM SWITCH
FINE ADJUSTMENT
12.
Tighten the LOCK NUT.
13.
If necessary readjust the vacuum with the FINE ADJUSTMENT SCREW.
14.
Switch off CASSETTE SUCKING and VACUUM PUMPS.
15.
Leave SERVICE MODE.
16.
Key in 3585 to bring all MOTORS to HOME POSITION.
KODAK AG, Stuttgart
SCREW
figure 2-15
2-19
3053-3
BRASS NUT
LOCK NUT
12/1998