Kodak MULTILOADER 700 Service Manual page 170

Hide thumbs Also See for MULTILOADER 700:
Table of Contents

Advertisement

3053-3
3
.
Enter SERVICE MODE FDAB,Day,Day,9,9.
Select Option 7.8.2 ( VACUUM PUMPS ).
Select Option 7.8.3 (CASSETTE SUCKING).
4
.
Cover CASSETTE SUCKERS with a FILM.
5
.
Adjust the Vacuum to -400 mBar -30 mBar with the BRASS NUT.
6
.
Tighten LOCKNUT.
7
.
Readjust if necessary with FINE ADJUSTMENT SCREW of VACUUM SWITCH.
8
.
Switch off VACUUM PUMP and deenergize SOLENOID VALVE.
9
.
Leave Service Mode.
10
. Key in 3585 to bring all MOTORS to HOME POSITION.
B. AIR PRESSURE OF CASSETTE BLOWING
PURPOSE:
Through the CASSETTE BLOWPIPES air is blown into the CASSETTE to separate a FILM
from the CASSETTE LID.
Note
DURING THIS ADJUSTMENT THE AIR RESERVOIR WILL BE EMPTY AFTER A FEW
SECONDS. IN THIS CASE DEENERGIZE THE SOLENOID VALVE AND WAIT UNTIL THE
COMPRESSOR STOPS. THEN ENERGISE THE SOLENOID VALVE AGAIN.
1
.
Connect PRESSURE GAUGE PN 9186781.
2
.
Enter SERVICE MODE FDAB ,Day,Day,9,9.
Select Option 7.3 (CASSETTE BLOWING ).
Note
Check that the BLOWPIPES are not clogged.
3
.
Adjust REGULATOR for 2 Bar - 30mBar. See the drawing on the next page.
4
.
Deenergize the SOLENOID VALVE "CASSETTE BLOWING".
5
.
Leave SERVICE MODE.
12/1998
4-84
ADJUSTMENTS
KODAK AG, Stuttgart