Kodak MULTILOADER 700 Service Manual page 42

Hide thumbs Also See for MULTILOADER 700:
Table of Contents

Advertisement

3053-3
11
. Connect MOTOR M11 and SWITCH S30.
FUNCTION TEST
1
.
Enter SERVICE MODE FDAB, Day, Day, 9, 9.
2
.
Select Option 7.8.2 (MOTOR VACUUM PUMPS).
3
.
Switch on VACUUM PUMP. PUMP runs for a short moment until vacuum reached the
set level.
4
.
Take off VACUUM TUBING. PUMP runs.
5
.
Switch off VACUUM PUMPS (press KEY # 2).
6
.
Connect VACUUM TUBING.
7
.
Connect the VACUUM GAUGE.
Connect the VACUUM GAUGE here
12/1998
figure 2-14
2-18
REPLACEMENTS
KODAK AG, Stuttgart