Kodak MULTILOADER 700 Service Manual page 172

Hide thumbs Also See for MULTILOADER 700:
Table of Contents

Advertisement

3053-3
2
.
Loosen LOCKNUT at VACUUM PUMP.
3
.
Enter SERVICE MODE FDAB ,Day,Day,9,9.
Select Option 7.8.2 ( VACUUM PUMPS).
Select Option 7.8.4 (MAGAZINE SUCKING).
4
.
Cover FILM POCKET SUCKERS with a sheet of FILM.
5
.
Adjust the VACUUM to -400 mBar - 30 mBar with BRASS NUT.
6
.
Tighten LOCKNUT.
7
.
Readjust if necessary with FINE ADJUSTMENT SCREW of VACUUM SWITCH.
8
.
Stop VACUUM PUMP and deenergize SOLENOID VALVE.
9
.
Leave SERVICE MODE.
10
. Key in 3585 to bring all MOTORS to HOME POSITION.
B. AIR PRESSURE OF FILM POCKET BLOWING
PURPOSE:
The pressure has to be in the correct range. If it is not correct, Films in the MAGAZINE may
not become separated.
Note
DURING THIS ADJUSTMENT THE AIR RESERVOIR WILL BE EMPTY AFTER A FEW
SECONDS. IN THIS CASE DEENERGIZE THE SOLENOID VALVE AND WAIT UNTIL THE
COMPRESSOR STOPS. THEN ENERGISE THE SOLENOID VALVE AGAIN.
1
.
Connect PRESSURE GAUGE PN 9186781. See the drawing on the next page.
2
.
Enter to SERVICE MODE FDAB ,Day,Day,9,9.
Select Option 7.8.4 (MAGAZINE BLOWING).
4
Adjust REGULATOR for 1.8 Bar ±0.1 Bar.
.
5
.
Denergize the SOLENOID VALVE "MAGAZINE BLOWING".
6
.
Leave SERVICE MODE.
7
.
Key in 3585 to bring all MOTORS to HOME POSITION
12/1998
4-86
ADJUSTMENTS
KODAK AG, Stuttgart

Advertisement