3Xe3/Ds3 Circuit Pack - Nortel Optical Multiservice Edge 6130 Planning Manual

Table of Contents

Advertisement

4-16 Hardware description

3xE3/DS3 circuit pack

The 3xE3/DS3 circuit pack can be installed in the tributary slots of the
OME6130 chassis.
pack.
The PEC for the 3xE3/DS3 circuit pack is listed in
Table 4-10

3xE3/DS3 circuit pack

3xE3/DS3 circuit pack
3xE3/DS3
Figure 4-11
3xE3/DS3 circuit pack faceplate
3XE3DS3
3xE3/DS3 functionality overview
The 3xE3/DS3 circuit pack supports the following:
Refer to the sections in
functionality supported.
Optical Multiservice Edge 6130
Figure 4-11
supports up to 3 E3/DS3 services (75 ohm)
mapping of E3/DS3 signals to VC3 containers
support for framed E3 (G.832) / DS3 (M13) or unframed signals
monitoring
supports E3/DS3 line and path PMs
supports unprotected and SNCP traffic protection schemes
each port can be independently configured to carry E3 or DS3 traffic. A
mix of E3 and DS3 services is supported.
OAM&P description on page 6-1
NT6Q92MA Rel 1.0 Iss 1 Standard September 2006
shows the faceplate of a 3xE3/DS3 circuit