Bay Equipping Rules; Shelf Equipping Rules - Nortel Optical Multiservice Edge 6130 Planning Manual

Table of Contents

Advertisement

8-4 Ordering information and system engineering rules

Bay equipping rules

This section provides equipping rules for OME6130 installation in a bay. The
OME6130 shelf can be mounted in a variety of telecommunications equipment
bays, including 19", 21", and 23" standard bays.
Refer to
Table 8-3
OME6130 equipment rack space requirements
Equipment
OME6130 shelf with dual DC power feeds (NT6Q60AA)
75 ohm BNC Termination Panel (NT6Q71EA)

Shelf equipping rules

This section lists the equipping rules for the OME6130 shelf.
For more information on the OME6130 chassis, refer to
Engineering rules
1 Each shelf at an OME6130 site is a stand-alone network element.
2 The node capability is provisioned to either STM-1 or STM-4 during initial
3 Each shelf requires the following components:
4 Each shelf is capable of supporting up to four tributary circuit packs (slots
5 No fiber slack storage is provided for fibers terminating on the OME6130
Optical Multiservice Edge 6130 NT6Q92MA Rel 1.0 Iss 1 Standard September 2006
Table 8-3
for OME6130 equipment rack space requirements.
commissioning. The two SFP interfaces of the 2x155/622M aggregate
circuit pack are operating at the rate of the node capability value. The
appropriate SFPs (i.e. STM-1 or STM-4 rate) must be selected for the
2x155/622M aggregate circuit pack.
— two power supply units (one in slot 1 and one in slot 3)
— one OAM circuit pack in slot 2
— one 2x155/622M aggregate circuit pack in slot 6
— one filler panel in slot 7 (slot reserved for future release)
— one filler panel for each slots 4, 5, 8 and 9 (if no tributary circuit packs
are used)
— one fan module in slot 10
Note: The SFPs interfaces must be ordered separately.
4, 5, 8 and 9).
shelf. Cable relief off the shelf can be handled using the routing brackets
provided with the OME6130 Assembly Kit.
Rack units required
4U
1U
Chassis on page
4-3.