Proxy ARP is supported on the LAN interface when the OME6130 NE is used
as a gateway NE. The gateway OME6130 NE responds to ARP requests for
the subtending NEs when Proxy ARP is enabled. The subtending NEs need to
be added as Proxy ARP neighbours at the gateway OME6130 NE.
The LAN interface can be configured from the Network interface application
available from the Configuration/DCN menu item in the local craft access
terminal. For a detailed procedures, see Provisioning and Protection Switching
Procedures, 323-1855-310. To know how to provision the IP address for the
LAN port, refer to Installation, Commissioning and Testing Procedures,
323-1855-201.
Craft interface
The Craft interface provides a mechanism to connect a local craft terminal PC
directly to the OME6130 network element for local access to the OME6130
network and subtending network elements.The Craft interface consists of a
10/100Base-T RJ-45 port located on the front of the OAM circuit pack.
The Craft port can be enabled or disabled with the default being enabled.
The Craft interface can be configured from the Network interface application
available from the Configuration/DCN menu item in the local craft access
terminal. For a detailed procedures, see Provisioning and Protection Switching
Procedures, 323-1855-310. To know how to provision the IP address for the
Craft port, refer to Installation, Commissioning and Testing Procedures,
323-1855-201.
M1/F1 interface
The M1/F1 interface provides a mechanism to connect a PC or a modem to the
OME6130 network element for user byte clear channel access or remote
management. The RS-232 serial port is exposed as a RJ-45 connector located
on the front of the OAM circuit pack.
The M1/F1 interface can be provisioned for two applications:
point-to-point protocol (ppp) - modem connectivity to the network element
through the RS-232 serial port based on IP over PPP
user data channel (udc) - F1 byte user data channel limited to asynchronous
mode at 9600 kbps. The F1 byte user data channel is supported only for the
STM-1/4 interfaces of the 2x155/622M aggregate circuit pack.
The serial port can be configured from the Serial Port application available
from the Configuration/DCN menu item in the local craft access terminal.
For more details, refer to Provisioning and Protection Switching Procedures,
323-1855-310.
Planning Guide NT6Q92MA Rel 1.0 Iss 1 Standard September 2006