6-30 OAM&P description
Viewing/provisioning path alarm profiles
The Path Alarm Profiles application in the Profiles menu of the local craft
access terminal provides the ability for users to view the eight default path
alarm profiles, or create/edit/delete a user defined path alarm profile. The path
alarm profile is then assigned and applied to the eight connection types
according to the STM Port Profile.
The path alarm profile specifies the consequent actions upon TIM, PLM and
UNEQ conditions. The path alarm profile also specifies the path level alarms
that should be masked. The eight default path alarm profiles can not be deleted
and their defined actions can not be modified, while the user can create or
delete the user defined path profiles and edit the defined actions.
Once a connection is created with the path alarm profile assigned according to
the STM Port Profile, the path alarm profile can be manually changed at the
AU/TU levels.
For detailed procedures on managing path alarm profiles, refer to Trouble
Clearing and Module Replacement Procedures, 323-1855-543.
Enable/disable facility alarm reporting
User can enable or disable all alarm reporting associated to the following
facilities / alarm object instances:
Once the alarm reporting is disabled for the facility / alarm object instance, any
active alarm will be suppressed and listed in the suppressed alarms application.
Viewing/provisioning environmental alarms
The OME6130 network element has 7 parallel telemetry input points. The
input points allow remote monitoring of other equipment in the office in which
the network element is located. For example, the input points can monitor
room temperature alarms or office door open alarms. Specific external alarm
must be set up during provisioning and are assigned to a specific contact pin.
The alarm input points are connected to the ALM.IN RJ-45 connector on the
front of the OAM circuit pack.
The Environmental alarm input application in the Configuration menu of
the local craft access terminal supports the provisioning of alarm for an alarm
input point.