Power Specifications - Nortel Optical Multiservice Edge 6130 Planning Manual

Table of Contents

Advertisement

Figure 7-1
OME6130 chassis - physical specifications
PSU (2)

Power specifications

The OME6130 equipped with the DC PSU operates from -40 V dc to -57.5 V
dc measured at the input terminals of the network element. The following
tables list the estimated power consumption for the different modules:
Table 7-3
Power consumption for common equipment at -54 V dc
Common equipment
2x155/622M aggregate circuit pack
Single feed DC Power Supply Unit
OAM circuit pack
Fan module
Chassis
OAM Tributary slots (4) Aggregate slots (2)
Table 7-3
lists the estimated power requirement for the common
equipment at -54 V dc
Table 7-4
lists the estimated power requirement for each interface circuit
pack -54 V dc
Table 7-5
lists the estimated power requirement for each small form-factor
pluggable (SFP) module at -54 V dc
Table 7-6
lists the recommended feeders for the chassis
Planning Guide NT6Q92MA Rel 1.0 Iss 1 Standard September 2006
Technical specifications 7-3
Fan
Typical
(W)
20
18
6
13
0