Function diagrams (see SINAMICS S110 List Manual)
● 4720 Encoder interface, receive signals, encoders n
● 4730 Encoder interface, send signals, encoders n
● 4735 Find reference mark with equivalent zero mark, encoders n
● 4740 Measuring probe evaluation, measured value memory, encoders n
Overview of important parameters (see SINAMICS S110 List Manual)
Adjustable parameter drive, CU_S parameter is marked
● p0418[0...15] Fine resolution Gx_XIST1
● p0419[0...15] Fine resolution Gx_XIST2
● p0480[0...2] CI: Signal source for encoder control word Gn_STW
● p0488[0...2] Measuring probe 1 input terminal
● p0489[0...2] Measuring probe 2 input terminal
● p0490 Invert measuring probe (CU_S)
Display parameters drive
● r0481[0...2] CO: Encoder status word Gn_ZSW
● r0482[0...2] CO: Encoder position actual value Gn_XIST1
● r0483[0...2] CO: Encoder position actual value Gn_XIST2
● r0487[0...2] CO: Diagnostic encoder control word Gn_STW
Drive functions
Function Manual, 10/2008, 6SL3097-4AB10-0BP0
Communication PROFIBUS DP
9.1 Communication according to PROFIdrive
427