Safety Integrated Functions
8.6 Controlling the safety functions
● Internal event (no active safety fault)
● Safe state
Figure 8-14
Safe state selection
F-DO features
● Failsafe design with two digital outputs (plus and minus switching)
● Status parameter r10052
● If the digital output is used for Safety Integrated functions, it is not available for other
Function diagrams (see SINAMICS S110 List Manual)
● 2853 Safety Integrated - Extended Functions (F-DO 0)
● 2856 Safety Integrated - Extended Functions, safe state selection
● 2857 Safety Integrated - Extended Functions, assignment F-DO 0
Overview of important parameters (see SINAMICS S110 List Manual)
● p10042[0..5] SI F-DO 0 signal sources
● r10052 CO/BO: SI status of digital outputs
338
For the creation of the Signal Safe State, the following signals can be called upon via
p10039[0...3]:
– Power removed (STO active)
– SS1 active
– SS2 active
– SOS active
– SLS active
The different signals selected through p10039 are logically linked by means of OR
operation. Result of these logic operations is the "Safe State".
digital outputs.
Function Manual, 10/2008, 6SL3097-4AB10-0BP0