General information for commissioning
1.2 BICO interconnection procedure in STARTER
Graphical screen interface
When carrying out BICO interconnection via the graphical screen interface, proceed as
follows:
For the set velocity, which is a 32-bit data type, you want to interconnect p parameter
p1155[0] for "Speed setpoint 1" with r parameter r2060[1], for example.
1. In the project navigator under Drive_1 > Open-loop/closed-loop control, double-click the
Figure 1-7
Interconnection via graphical screen interface 2
28
selection Setpoint addition.
Function Manual, 10/2008, 6SL3097-4AB10-0BP0