Safety Integrated Functions
8.9 Acceptance test and acceptance report
8.9.5

Completion of certificate

SI parameters
Control Unit
Power Module
Checksums
Name
Safety logbook
Checksums
Time stamp
Data backup
Parameter
PLC program
Circuit diagrams
Countersignatures
Commissioning engineer
This confirms that the tests and checks have been carried out properly.
Date
Machine manufacturer
This confirms that the parameters recorded above are correct.
Date
382
Drive
Drive number
Functional
r9781[0] =
r9782[0] =
Type
Name
Name
Specified values checked? (check)
Yes
Control Unit (p9798)
Hardware components
r9781[1] =
r9782[1] =
Storage medium
Designation
Company/dept.
Company/dept.
No
Checksum (8 hex)
Power Module (p9898)
Storage location
Date
Signature
Signature