2.3

Connection via serial interface

Prerequisite
There must be a serial interface (COM) on the PC from which the connection is to be made.
Settings
1. In the STARTER, go to Project > Set PG/PC interface and select the Serial cable (PPI)
2. Enter the following settings. The "0" address and the transmission rate (e.g. 19.2 kbit/s)
Figure 2-2
Setting the interface
Drive functions
Function Manual, 10/2008, 6SL3097-4AB10-0BP0
interface.
If this interface is not in the selection list, you will first have to add it using Select.
Note
If the interface cannot be added to the selection menu, the driver for the serial interface
has to be installed.
This is located under the following path on the STARTER CD:
\installation\starter\starter\Disk1\SerialCable_PPI\
The STARTER must not be active while the driver is being installed.
are important here.
Commissioning preparations for PROFIBUS
2.3 Connection via serial interface
41