Effect of the acceptance test on specific measures
Table 8- 13
Scope of the acceptance test depending on specific measures
Measure
Replacement of the
encoder system
Replacement of an
SMC/SME Module
Replacement of a
motor with DRIVE-
CLiQ
Replacing the Control
Unit
Replacing the Power
Module or Safe Brake
Relay
Replacement of SI-
relevant distributed I/O
devices (e.g.
EMERGENCY OFF
switch)
Firmware - upgrade
(CU/Sensor Modules)
Change to a single
limit (e.g. SLS limit)
Enhancement of
functions (e.g.
additional actuator,
additional SLS stage)
Transfer of project
data to other machines
via series
commissioning
Drive functions
Function Manual, 10/2008, 6SL3097-4AB10-0BP0
Documentation
No
Supplementation of
hardware
data/configuration/soft
ware version data
Supplementation of
hardware
data/configuration/soft
ware version data
Supplementation of
hardware
data/configuration/soft
ware version data
Supplementing
hardware
data/configuration
Supplementation of
hardware
data/configuration/soft
ware version data
Supplementation
Version data
Supplementing the SI
function
Supplementing SI
functions or function
table
Possibly supplement
to the machine
description (check of
the firmware version)
Function test Part 1
Function test Part 2
No
Test of failsafe actual
value acquisition
No
Test of failsafe actual
value acquisition
No
Test of failsafe actual
value acquisition
No
Partially, if the system
scan cycle times or the
dynamic response
were changed (drive-
specific)
Yes
No
Yes,
No
with comment
restriction to replaced
components
Yes,
Yes,
including a note
if the system scan
informing of the time of
cycle times or the
implementation of the
dynamic response
new functionality
were changed or test
of the new functionality
No
Partially,
test of the changed
limit
Yes, with note
Partially,
restriction to adapted
test of any additional
parts as required
limits
Yes, with note
No,
if no changes were
made to SI parameters
Safety Integrated Functions
8.9 Acceptance test and acceptance report
Conclusion of the
report
Supplementation
New checksums and
countersignature as
required
Supplementation
New checksums and
countersignature
Supplementation
New checksums and
countersignature
Supplementation
New checksums and
countersignature as
required
Supplementing and
countersigning
No
Supplementation
New checksums and
countersignature as
required
Supplementation
New checksums and
countersignature
Supplementation
New checksums and
countersignature as
required
No, if data are
identical (check of
checksums)
363