Velocity Factor
Vertical
Back Porch
Vertical
Frnt Porch
V
Softkey in the more cal menu. Enters the velocity factor used by the
analyzer to calculate equivalent electrical length. Values entered
should be less than 1, however the analyzer accepts values from 0.01 to
1.2.
Access Keys:
CAL
Softkey in the more CRT adjust menu. This is the CRT timing
adjustment for use with external monitors. Also affects the network
analyzer's internal CRT. Default setting is 31.84 µsec. This setting is
not affected by an instrument preset.
See
"Using an External VGA Monitor" on page 4-87
information.
Access Keys:
SYSTEM OPTIONS
More
Softkey in the more CRT adjust menu. This is the CRT timing
adjustment for use with external monitors. Also affects the network
analyzer's internal CRT. Default setting is 16.68416 msec. This setting
is not affected by an instrument preset.
See
"Using an External VGA Monitor" on page 4-87
information.
Access Keys:
SYSTEM OPTIONS
More
ES User's Guide
More Cal
System Config
System Config
Hardkey/Softkey Reference
for more
CRT Adjust
for more
CRT Adjust
8-97