CHECKING THE MACHINE START CONTROL

Attempt to start the engine with the forward or reverse
gear put.
The engine must not start. If the engine starts, contact
the TEREXLIFT Technical Service.
Repeat the operation putting first one gear, then
the other.

CHECKING THE STATE OF THE STRUCTURE

Five years or 6000 hours after the fi rst placing into
operation of the machine (whichever occurs fi rst),
check the state of the structure paying an extreme
attention to the welded supporting joints and the pins
of both boom and platform (if present).
WARNING
After the fi rst 5 years, repeat this check every
2 years.
Part No. 57.0009.0540
GTH-4013 SX - GTH-4017 SX - GTH-4013 EX - GTH-4017 EX

SEAT SWITCH

Located inside the seat cushion, this micro switch
prevents any machine transmission movements if the
operator is not correctly seated in the driving seat.
Checking the seat switch (at every use)
To check if the seat switch is in efficient working order,
it will be enough to attempt to make the machine to
move without sitting on the drive seat.
In this condition, the machine shall not move.
Should that not be the case, contact TEREXLIFT
Technical Service.
NOTICE
See section ROUTINE CHECK SCHEDULE for
noting the result of the daily safety devices
checking.