PROBLEM
THE DASHBOARD
DOES NOT TURN ON
THE STARTER DOES
NOT RUN
THE STARTER RUNS,
BUT THE ENGINE
DOES NOT START
THE MACHINE
DOES NOT MOVE
FORWARD/BACK
NO SELECTION
OF THE STEERING
MODE
THE LOAD LIMITING
SYSTEM IS IN
ALARM
NOTICE
In case of faults not listed in this chapter, address to the TEREXLIFT Technical Assistance, your
nearest authorized workshop or dealer.
Part No. 57.0009.0540
Faults And Troubleshooting
CAUSES
Battery down
Fuse in the engine
compartment box blown
Forward/reverse gear selector
not in neutral position
Battery down
Engine start fuse blown: F1G
for SX or F20 for EX
No fuel
Fuel filter clogged
Fuel hose empty (fuel used up)
Operator is not correctly seated
in the driving seat
Parking brake engaged
Outriggers lowered
Fuse F14 - F18 blown
Fuse blown: F5 for SX or F24
for EX
• Fuse blown: F25 for SX or F24 for EX
• System failure
GTH-4013 SX - GTH-4017 SX - GTH-4013 EX - GTH-4017 EX
WARNING
Any repair work, maintenance or troubleshooting
must be carried out with machine stopped, boom
in rest position or laid on the ground, parking
brake engaged and ignition key removed.
SOLUTIONS
Check the battery condition
Check the main fuse in the engine
compartment and replace if
necessary
Set the switch to 0
Recharge or replace the battery
Check the fuse located i and
replace if necessary
Refuel
Change the filter. See engine
operator handbook)
Refuel, then refer to engine
operator handbook
Sit correctly in the driving seat
Disengage
Lift the outriggers
Check the fuse and replace if
necessary.
Check the fuse and replace if
necessary.
• Check and replace fuse, if necessary
• Check the load cell functionality