Ground Control Box - Genie GS-69 Series Instructions Manual

Inspection and repair
Table of Contents

Advertisement

Inspection and Repair Instructions
Procedure
Note: Perform this procedure on a firm, level
surface with the machine in the stowed position. At
the ground control box, turn the key switch to the
off position and push in the red Emergency Stop
button.

Ground Control Box

1 On the ground controls side of the machine,
open the compartment door.
2 Remove the retaining fastener that secures the
ground control panel and set aside. Open the
control box. Refer to illustration 1, item A.
illustration 1
3 Locate the ECU (U5) in the control box. Trace
the white wire from connector J2 pin C8 to the
terminal strip. Refer to illustration 2.
4
4 Trace the white/black wire from connector J2
pin C9 to the terminal strip.
Refer to illustration 2.
If the white wire is located in terminal strip 11
and the white/black is in 6. Continue to Axle
Limit Switches.
The wires are in the incorrect location.
Continue with step 5.
J12
J2-C9
WH/BK
J2-C8
WH
A
5 Correct the location of the 2 wires in the
terminal strip. Continue to Axle Limit
Switches.
Note: Do not close the control box at this time.
GS-69 RT Models
J11
J10
J9
J8
J7
J2
U5
illustration 2
REV A
J6
J5
WH
WH/BK
J1
Part No. 237339