Maintenance

SAFETY SWITCHES:

L Low boom sensor: switch installed at the
back of the boom.
M High boom sensor: switch installed at the
back of the boom.
N Extended boom sensor: switch installed at
the back of the boom (for GTH 4013 SX &
GTH 4013 EX)
O Extended boom sensor: switch installed at
the back of the boom (for GTH 4017 SX &
GTH 4017 EX)
1 Switch on the parking brake: when the par-
king brake is engaged, it stops the machine
travel.
2 Switch on the parking brake: when the
parking brake is engaged, this pressure switch
activates the warning lights 39 present in the
instruments panel.
Switch control
(at every use)
Switch L on boom
Lift the boom with a tilt angle below 20° and check
if, regardless of the boom extension, machine
sway function and outriggers controls can be
activated.
If they cannot be activated, call TEREXLIFT
Technical Assistance Service.
Switch M on boom
Lift the boom with a tilt angle over 50° and make
sure the machine sway function and outriggers'
controls are disabled.
If they are not disabled, call TEREXLIFT
Technical Assistance Service.
Switch N and O on boom
Lift the boom with a tilt angle between 20°
and 50°, extend the boom and make sure the
machine sway function and outriggers controls
are disabled.
If they are not disabled, call TEREXLIFT
Technical Assistance Service.
120
GTH-4013 SX - GTH-4017 SX - GTH-4013 EX - GTH-4017 EX
First Edition - Second Printing
Switches 1 and 2 on the parking brake
Engage the parking brake and start the engine.
The warning light 39 should come on.
Attempt to move with the machine. The machine
must not move.
Should that not be the case, contact the TEREXLIFT
Technical Service.
C
N
L
M
o
50°
B
20°
A
Part No. 57.0009.0540