Maintenance

CHECKING THE SAFETY DEVICES

LOAD LIMITING SYSTEM.

It consists of a load cell fitted to the rear axle and
a display installed in the driving place. This device
enables the operator to check the stability variation
through a bar with 6 LED's (2 green, 2 orange and
2 red).
116
GTH-4013 SX - GTH-4017 SX - GTH-4013 EX - GTH-4017 EX
First Edition - Second Printing
Checking the load limiting system
(at every use)
When power is turned on, the load limiting system
runs a self-test. In the case of troubles, the limiter
enters the safety mode blocking any dangerous
manoeuvres: LED L6 starts flashing representing
an alarm code.
The meaning of these alarm codes is shown in section
"Faults and Troubleshooting".
To do a manual check, it will be enough to load a
weight exceeding the maximum permitted with the
boom fully out and attempt to lift it. The system shall
enter in alarm; should that not be the case, contact
TEREXLIFT Technical Service.