M oving Around
1
the Analyzer
Interface
8-2 Timing: Using the Analyzer
The Timing Analyzer Softkey Interface uses eight screens to
display analyzer information. Each screen has a set of associated
functions. Some of the functions are common to all of the screens
and some of the functions are specific to a particular screen.
The interface has three "specification" screens that are used to set
up the measurement environment; two output screens, one graphic
and one tabular; a screen to enter and display native analyzer
("pod") commands; and two screens to display logging information,
one for errors and one for analyzer events.
You use the "display" command to change from one screen to the
other. The "display" command has the following options:
Trace Specification
which controls the data acquisition mode,
trigger condition definition, and sample rate.
Format Specification which controls the probe, including the
definition of labels that refer to probe
signals.
Post Process
which defines procedures to be executed
Specification
after each trace measurement.
Timing Diagram
which displays the measurement data in a
graphic form.
Trace List
which displays the measurement data in
tabular form.
Pod Commands
which allows you to send some native
analyzer specific commands and to display
the responses.
Error Log
which displays a log of command line errors.
Event Log
which displays a log of analyzer events.