Figure 5-7. Slave Clocks

demux
When the slave clock mode is "demux", only the
lower eight external channels (0-7) are used.
The slave clock (as specified by your answers to
the next four questions) latches these bits and
the emulation clock samples the same channels
again. The latched bits show up as bits 0-7 in the
trace data, and the second sample shows up as
bits 8-15 (see figure 5-8).
If no slave clock has appeared since the last
master clock, the data on the lower 8 bits of the
pod will be the same as the upper 8 bits. If more
than one slave clock has appeared since the last
master clock, only the first slave data will be
available to the analyzer.