Function
This command controls the display format for the timing diagram
and trace list. The timing diagram display can include all defined
labels or any combination of blank lines, labels or label bits, or
compare file labels or label bits (if the compare file has been
selected). The trace list display can include all labels or any
combination of time counts, mark names, labels or label bits, or
compare file labels or label bits (if the compare file has been
selected).
In the timing diagram, entering the display command with no
options allows you to toggle the between the default labels
referring to probe signals and the user-defined labels.
Labels display from a compare file have a trailing "x" appended to
indicate an external reference.
Default Values
All defined labels are displayed by default.
Parameters
all_labels
blank
< BIT# >
compare_file
< DISPLY>
This option displays all of the labels
currently defined in the format specification.
This timing diagram option inserts a blank
line in the display.
This prompts you to enter the integer bit
number.
This option selects the compare file labels
for display. This is available only when a
compare file has been defined in the post
process specification. The softkey label
appears as < COMPAR> if a compare file
has not been selected. User-defined labels
from the compare file are displayed with a
trailing "x" to designate an external reference.
This timing diagram softkey label is used to
remind the you that the display command
without parameters is used to toggle
Timing: Commands 9-65