The configuration file loaded has not configured the external
analyzer for Timing measurements. This can be accomplished by
entering the emulation interface and modifying the configuration.
The configuration questions that need to be answered are as follows:
Modify external analyzer configuration: yes
Should emulation control the external bits: yes
External analyzer mode? timing
NOTE: To make this the default powerup configuration, save the
configuration file as userconfig.EA in the associated product directory.
/usr/hp64000/inst/emul/<product_number>/userconfig.
C-2 Timing Messages
STATUS: External analysis not configured for timing
This message appears when the configuration file loaded into the
emulator/analyzer has not been configured for external timing
analysis. The following message also appears:
The emulation software is used to modify and load the new
configuration, as indicated by the message. See "Configuring the
External Analyzer" in "Using the External Analyzer" in this manual
and the "Emulation Configuration" chapter in the HP64700-Series
Emulators Softkey Interface Reference for more information.
STATUS: Indicated max_min/mean_stdv forced halt at 9999 runs
This message indicates that a repetitive execution has been halted
to avoid an overflow on the counter. Only 9999 runs can be
executed.
STATUS: Mark found on sample number < sample>
This message is displayed when the find command locates on of the
four marks (abcd).
STATUS: HP64700 I/O error; communications timed out
This message indicates that the communications connection has
been lost or interrupted. No further communications will be made
between the Timing Analyzer software and the emulator. The usual
response is to end the session, which must release the system, and
restart the emulator. Analysis of current trace data may be
possible, however. Check for loose cables before restarting the
Timing Analyzer.