D isplaying in
1
Absolute Format
Trace List
Label:
Address
Data
Base:
hex
hex
+200
06017C
+201
06017A
+202
000B06
+203
000B16
+204
000B08
+205
000AF8
+206
000AFA
+207
000B16
+208
000AFC
+209
000AFE
+210
06017A
+211
06017C
+212
000B00
+213
060090
+214
000B02
STATUS:
M68000--Running user program
display
trace
absolute
run
trace
3-6 Displaying Traces
The "absolute" trace display option allows you to display status
information in absolute format (binary, hex, or mnemonic). The
"absolute status mnemonic" display is the same as default
mnemonic display, except that opcodes are not disassembled.
Offset=0
Absolute Status
0090
11101100
0006
11101100
66F0
10110110
6765
10101111
60E0
10110110
1012
10110110
4880
10110110
6765
10101111
2053
10110110
3080
10110110
0006
11101110
0090
11101110
5493
10110110
0067
11101100
528A
10110110
status
binary
step
display
More data off screen (ctrl-F, ctrl-G)
binary
Emulation trace complete______...R....
modify
break
time count
relative
480
nS
520
nS
480
nS
1.0
uS
520
nS
720
nS
520
nS
480
nS
520
nS
480
nS
520
nS
480
nS
520
nS
480
nS
520
nS
end
---ETC--

Advertisement

Table of Contents
loading

Table of Contents