CDM-625 Advanced Satellite Modem
Remote Control
Command
Parameter
(Instruction
Type
& Qualifier)
BUC
N/A
4 bytes
DC
Current
BUC
N/A
4 bytes
Voltage
BUC
N/A
4 bytes
Output Power
Level
BUC
N/A
4 bytes
Temperature
BUC
N/A
1 byte, value
Phase Lock
of 0 or 1
Loop
BUC
N/A
2 bytes
Software
Version
Number of
Description of Arguments
Arguments
Query only.
Indicates the value of the BUC DC current, in the form: xxxx,
where xxxx is between 0 and 9999, units mA.
If not available, response is 0000.
Query only.
Indicates the value of the BUC Voltage, in the form: xx.x, where
xx.x is between 0 and 64.0, units in volts.
Query only.
BUC Output power Level, where xx.x is the value in dBm.
Returns xxxx when FSK and BUC power are not enabled.
Example: BOL=37.4
Query only.
BUC temperature, in the form: sxxx, where
s = sign
xxx = number
Note: This query is only valid when the FSK and BUC power are
turned On.
Query only.
BUC phase lock loop:
0=Locked
1=Unlocked
Note: This query is only valid when the FSK and BUC power are
turned On.
Query only.
BUC software version, where xx is between 0 and 15.
Note: This query is only valid when the FSK and BUC power are
turned On.
D–55
Revision 1
MN-0000036 (Ref MN/CDM625.IOM)
Response
Query
to
(Instruction &
Response to Query
Command
Qualifier)
N/A
BDC?
BDC=xxxx
(see description of
arguments)
Exception
600L emulation:
ODC?
N/A
BDV?
BDV=xx.x
(see description of
arguments)
Exception
600L emulation:
ODV?
N/A
BOL?
BOL=xx.x
(see description of
arguments)
Exception
600L emulation:
OOL?
N/A
BUT?
BUT=sxxx
(see description of
arguments)
Exception
600L emulation:
ODT?
N/A
BPA?
BPA=x
(see description of
arguments)
Exception
600L emulation:
OLL?
N/A
BSV?
BSV=xx
(see description of
arguments)
Exception
600L emulation:
OSV?

Advertisement